Description
Key Features
- Ventilation Modes:
- BiPAP S/T (Spontaneous/Timed): Adjusts IPAP/EPAP with backup respiratory rate.
- CPAP: Continuous positive airway pressure for stable patients.
- AVAPS (Average Volume-Assured Pressure Support): Maintains target tidal volume for patients with variable breathing.
- PC (Pressure Control): For patients requiring full ventilatory support.
- Pressure Ranges:
- IPAP: 4–40 cm H₂O (inspiratory pressure).
- EPAP: 4–25 cm H₂O (expiratory pressure).
- Oxygen Blending: Compatible with external oxygen sources (21–100% FiO₂).
- Integrated Humidifier: Heated humidification for patient comfort.
- Smart Monitoring:
- Real-time waveforms (pressure, flow, volume).
- Built-in pulse oximetry integration (optional).
- Data logging via Philips Care Orchestrator (cloud-based platform).
- Portability: Battery-operated (up to 10+ hours) for transport.
Technical Specifications
Parameter | Details |
Dimensions | 30 x 25 x 15 cm (compact design). |
Weight | ~6–8 kg (portable with handle). |
Power Supply | 100–240V AC + 24V DC battery backup. |
Display | Touchscreen interface with intuitive menus. |
Alarms | Apnea, low/high pressure, disconnection, power failure. |
Compatibility | Adult, pediatric, and neonatal patients. |
Safety Recall (2021)
- Affected Devices: Certain Philips ventilators/BiPAPs (PE-PUR foam degradation risk).
- Trilogy Status: Verify if your device is included via Philips Recall Portal.
- Philips’ Response: Offers free repairs/replacements with silicone foam.
Applications
- Chronic Respiratory Failure: COPD, ALS, muscular dystrophy.
- Post-Surgical Care: Weaning from mechanical ventilation.
- Neuromuscular Disorders: Spinal cord injuries, myasthenia gravis.
- Home Ventilation: Long-term support for tracheostomy patients.
Setup & Operation
- Mode Selection: Choose BiPAP S/T, CPAP, AVAPS, or PC per prescription.
- Set Parameters: Adjust IPAP, EPAP, FiO₂, backup rate, and tidal volume.
- Attach Interface: Connect mask, nasal pillows, or tracheostomy tube.
- Monitor: Use touchscreen or Care Orchestrator for real-time data.
Maintenance
- Daily: Clean humidifier chamber and replace filters.
- Weekly: Disinfect tubing and mask.
- Monthly: Replace air filters and check seals.
- Annual: Professional servicing recommended.
Key Takeaways
- The Philips Trilogy BiPAP is a hospital-grade ventilator ideal for severe respiratory conditions requiring precise pressure control.
- Requires clinical training for setup and monitoring.
For home use, pair with Philips Care Orchestrator for remote monitoring. Always consult a pulmonologist or respiratory therapist to configure settings. For support, contact Healthcare Needs directly.